The oil bottle is provided with Hydrajaws Model 2000 and Model 2050 testers to allow the user to top up the oil reservoir should this be necessary.
The need to perform an oil top up will vary depending how much the tester is used, in fact how many times the gauge is removed from the device is the deciding factor.
The oil loss is small but does occur every time the gauge is removed, therefore overtime this essential but straight forward onsite maintenance is necessary.
If the Hydrajaws tester is allows to run out of oil then the tester will stop working though is fully recoverable.
Assuming the tester features a detachable gauge arrangement - the tester may simply be out of oil. Follow the oil fill procedure to refill the tester using the dedicated oil bottle.
What oil type is recommended?
Any light mineral hydraulic oil will suffice. The important number is ISO Viscosity Grade 32.